GeneProof Bordetella pertussis/parapertussis PCR Kit
Kat.: BP/ISEX/100
A termék CE/IVD minősítéssel rendelkezik és az OGYÉI által nyilvántartásba vett.
Az Bordetella pertussis és Bordetella parapertussis elkülönítésére és detektálására alkalmas ‘Ready-to-Use ‘ master mix. Az IS1002 (mind a Bordetella pertussisra/parapertussisra specifikus) és az IS1001 (csak a B. parapertussisra jellemző) több kópiás inszertációs szekvenciák amplifikációja. (100 reakció)
Leírás
PRODUCT ADVANTAGES
MORE INFORMATION WITH LESS SAMPLES
- Detects and distinguishes Bordetella pertussis and Bordetella parapertussis in a single reaction tube
 
UNIVERSAL PCR PROFILE
- Easily combinable with other PCR kits from the Respiratory Infections group, especially with GeneProof Mycoplasma pneumoniae PCR Kit and GeneProof Chlamydia pneumonia PCR Kit
 - Simplifies laboratory workflow
 
HIGHLY SPECIFIC DETECTION
- Amplification of the multi-copy insertion sequences IS1002 (specific for both Bordetella pertussis/parapertussis) and IS1001 (specific only for B. parapertussis)
 - No false-positive results for Bordetella holmesii
 
CONTAMINATION ELIMINATION
- Ready-to-Use Master Mix contains Uracil-DNA glycosylase (UNG) and dUTPs eliminating possible contamination with amplification products
 
COMPATIBLE WITH A WIDE RANGE OF REAL-TIME PCR DEVICES
CE IVD CERTIFIED DIAGNOSTIC TEST
Technical specification
| Indication | in vitro diagnostic medical device | 
| Intended User | For professional use in laboratories with trained staff | 
| Technology | real-time PCR | 
| Type of Analysis | qualitative | 
| Target Sequence | the multi-copy insertion sequences IS1002 (specific for both Bordetella pertussis/parapertussis) and IS10001 (specific only for B. parapertussis) | 
| Analytical Specificity | B. pertussis, 100 % B. parapertussis, 100 %  | 
| Analytical Sensitivity (LoD) | reaches up to 0.212 cp/µl with the probability 95 % (on Amplirun® Bordetella pertussis DNA control, Vircell) | 
| Extraction/Inhibition Control | PCR inhibition and DNA extraction efficiency control | 
| Validated Specimen | aspirate, sputum, swab | 
| Storage | -20 ± 5 °C | 
| Validated Extraction Methods | croBEE NA16 Nucleic Acid Extraction System GeneProof PathogenFree DNA Isolation Kit  | 
| Instruments | croBEE Real-Time PCR System* AriaMx Real-Time PCR System CFX96™ / Dx Real-Time PCR Detection System LightCycler® 480 LineGene 9600 / 9600 Plus Mic qPCR Cycler QuantStudio™ 5 Real-Time PCR System Rotor-Gene 3000 / Q SLAN® Real-Time PCR System  | 
| Required Detection Channels | FAM, HEX, Cy5 | 
| External Quality Assessment | regularly tested by QCMD and Instand e.V. External Quality Assessment panels – for results see www.geneproof.com | 
| Certification | CE IVD | 
*Validated instruments
            