GeneProof Parvovirus B19 PCR Kit
Kat.: B19/ISEX/025
A termék CE/IVD minősítéssel rendelkezik és az OGYÉI által nyilvántartásba vett.
A Parvovírus B19 detektálására alkalmas ‘Ready-to-Use ‘ master mix. A VP1 fehérjét (kapszid fehérjét) kódoló egyetlen kópiás gén specifikus konzervatív DNS-szekvenciáját célozza. (25 reakció)
Leírás
PRODUCT ADVANTAGES
HIGH SENSITIVITY AND TRACEABILITY
- Sensitivity was established with certified strain (NIBSC 3rd WHO International standard 12/208)
PRECISE QUANTITATIVE DETECTION
- Precise and fully traceable quantification according NIBSC 3rd WHO International standard 12/208
CONTAMINATION ELIMINATION
- Ready-to-Use Master Mix contains Uracil-DNA glycosylase (UNG) and dUTPs eliminating contamination with amplification products
COMPATIBLE WITH A WIDE RANGE OF REAL-TIME PCR DEVICES
CE IVD CERTIFIED DIAGNOSTIC TEST
Technical specification
Indication | in vitro diagnostic medical device |
Intended User | For professional use in laboratories with trained staff |
Technology | real-time PCR |
Type of Analysis | qualitative and quantitative |
Target Sequence | specific conservative DNA sequence of a single copy gene encoding VP1 protein (capsid protein) |
Analytic Specificity | Parvovirus B19, 100 % |
Analytic Sensitivity (LoD) | reaches up to 90.29 IU/ml with the probability of 95 % (on Parvovirus B19 NIBSC 12/208 using manual extraction GeneProof PathogenFree DNA Isolation Kit) reaches up to 156.7 IU/ml with the probability of 95 % (on Parvovirus B19 NIBSC 12/208 using automatic extraction croBEE NA16 Nucleic Acid Extraction System) |
Linear Range | 108 – 102.5 IU/ml with precision of ± 0.5 log (using manual extraction GeneProof PathogenFree DNA Isolation Kit or automatic extraction croBEE NA16 Nucleic Acid Extraction System) |
Dynamic Range | 108 – 90.29 IU/ml (using manual extraction GeneProof PathogenFree DNA Isolation Kit) 108 – 156.7 IU/ml (using automatic extraction croBEE NA16 Nucleic Acid Extraction System) |
Reporting Units | IU/μl |
Conversion Factor | 1 IU = 1.6 cp |
Metrological Tracebility | Parvovirus B19 NIBSC 12/208 |
Extraction/Inhibition Control | PCR inhibition and DNA extraction efficiency control |
Validated Specimen | plasma, whole blood |
Storage | -20 ± 5 °C |
Validated Extraction Method | croBEE NA16 Nucleic Acid Extraction System GeneProof PathogenFree DNA Isolation Kit |
Instruments | croBEE Real-Time PCR System Applied Biosystems 7300 / 7500 Real-Time PCR System CFX Connect™ / CFX96™ / Dx Real-Time PCR Detection System LightCycler 480 LineGene 9600 Plus Mic qPCR Cycler Rotor-Gene 3000 / 6000 / Q QuantStudio™ 3 / 5 Real-Time PCR System StepOne™ / StepOnePlus™ Real-Time PCR System SLAN® Real-Time PCR System |
Required Detection Channels | FAM, HEX |
External Quality Assessment | Regularly tested by QCMD and Instand e.V. External Quality Assessment Panels – results at www.geneproof.com |
Certification | CE IVD |